TENSOMETRIC SENSOR PR6211
The PR 6211 range of load cells is specially designed for weighing silos, tanks and process vessels.
Due to its high strength it is ideally suited to work in difficult and demanding technological conditions, guaranteeing reliability. Thanks to the hermetic housing in the IP68 standard, these sensors can operate in a wide temperature range and without loss of measurement parameters, they withstand overload of up to 150% of the nominal load. The offer also includes a sensor version for use in the potentially explosive zone (operating range: 500kg to 10t) and a version for working in high ambient temperature (operating range: from 500k to 5t).
Application:
- Platform scales
- Tank scales
- Weighing crucibles / furnace at high temperature
Basic technical parameters of PR6211:
- measurement range: 30kg, 50kg, 100kg, 200kg, 300kg, 500kg, 1t, 2t, 3t, 5t, 10t
- accuracy class: D1 (0.05% of the measuring range for sensors up to 300kg, 0.04% for others), L (0.25% of the measuring range)
- execution: stainless steel
- tightness class: IP68
- working temperature: from -30 to +95 ° C, with parameters from -10 to +85 ° C (for sensors up to 300kg) and from -10 to +55 ° C (for sensors above 300kg)
- working temperature of PR6211 LT sensors (high temperature version): from -40 to +180 degrees Celsius with parameters from -10 to +155 degrees centigrade
- sensor supply: 4 ... 24 V
- output signal: 2mV / V
- input impedance: 1300 +/- 50 Ohm (for L class sensors up to 300kg)
- 650 +/- 50 Ohm (for L class sensors above 300kg)
- 1300 +/- 12 Ohm (for class D1 sensors up to 300kg)
- 650 +/- 6 Ohms (for class D1 sensors over 300kg)
- 1200 +/- 200 Ohm (for LT sensors)
- output impedance: 1200 +/- 6 Ohm (for L class sensors up to 300kg)
- 610 +/- 3 Ohms (for L class sensors above 300kg)
- 1200 +/- 2 Ohms (for class D1 sensors up to 300kg)
- 610 + / 1 6 Ohm (for class D1 sensors over 300kg)
- 1200 +/- 6 Ohms (for LT sensors)
- intrinsically safe version: EEx ib IIC T6 (PTB No. Ex-92.C.2137)
- II 1G EEx ia IIC T6 (PTB 02 ATEX 2059)
Examples of sensor numbers:
- PR6211/31D1 30 kg 2mV/V 25.2 3m 9405 262 11311
- PR6211/51D1 50 kg 2mV/V 25.2 3m 9405 262 11511
- PR6211/12D1 100 kg 2mV/V 25.2 3m 9405 262 11121
- PR6211/22D1 200 kg 2mV/V 25.2 3m 9405 262 11221
- PR6211/32D1 300 kg 2mV/V 25.2 3m 9405 262 11321
- PR6211/52D1 500 kg 2mV/V 46.4 5m 9405 262 11521
- PR6211/13D1 1 t 2mV/V 46.4 5m 9405 262 11131
- PR6211/23D1 2 t 2mV/V 46.4 5m 9405 262 11231
- PR6211/33D1 3 t 2mV/V 46.4 5m 9405 262 11331
- PR6211/53D1 5 t 2mV/V 46.4 5m 9405 262 11531
- PR6211/14D1 10 t 2mV/V 46.4 5m 9405 262 11141
*a version adapted to work in the Ex zone is also available
**version adapted to work at high temperatures
Cable: shielded,
Cover: TPE,
Version: PR 6211/...D1E: blue color for PR 6211/...LT: PFA – red color
Diameter: 5 mm,
PR 6211/ from 500kg up to 10t: 3mm, 4 x 0,13 mm2
Lenght: 5 m
PR 6211/ from 30 up to 300kg: 3m
Certificate of conformity:
Version PR 6211 / .. D1E (from 500kg to 10t) II 1G EEx ia IIC T6, II 1D IP65 85oC
Accuracy class: D1, D1Ex, LT (for high temperatures)
Range: from 30 to 5000kg